A tracked construction machine operating in Spain developed gear-oil leakage around the final-drive hub only after continuous travel.
When parked cold, the area could remain dry.
Short-duration movement also did not always reproduce the leak.
The symptom became more visible after the final drive had rotated for a longer period and reached operating temperature.
This temperature and rotation dependency narrowed the fault toward the dynamic sealing interface.
Inspection did not reveal a strong fault in:
Because bearing play can disturb seal alignment, bearing condition was important to exclude before focusing only on the seal.
Many tracked final drives use a floating or Duo-Cone style mechanical face seal.
The simplified arrangement is:
Two precision seal rings → Faces run against each other → Elastomeric loading components position and load the rings
The sealing function depends on:
If those conditions are incorrect:
Cold static joint may appear sealed → Rotation and heat change face behavior → Oil begins escaping
The machine was observed through:
Leakage increased only after continued rotation.
That made a simple static O-ring leak less likely.
The key boundary became:
housing leaks because a stationary seal is damaged
versus
housing leaks because the rotating face seal loses correct contact during operation.
Inspection of the floating-seal assembly focused on:
Improper handling or contamination of precision seal faces can influence performance even when the components appear visually installed.
A worn bearing can affect seal alignment, but the bearings in this case did not show the evidence needed to explain the leak.
The diagnosis therefore remained at the rotating seal interface.
This avoided unnecessary work on the planetary gear system.
The face-seal system was restored using the machine manufacturer’s installation procedure.
After assembly, the final drive was tested through sustained travel to reproduce the original thermal condition.
The verification required more than a static leak check.
This Spanish tracked-equipment case demonstrates the value of comparing cold static sealing with hot dynamic sealing.
A final drive that stays dry while parked can still develop leakage when a floating mechanical seal loses correct face loading during rotation.
Yes. Dynamic face condition, thermal expansion and rotational behavior can make leakage appear mainly after operation.
No. It is a mechanical face-sealing system with a different operating principle.